[vc_row][vc_column][vc_row_inner][vc_column_inner width=”3/4″][vc_column_text]
The electromagnetic system helps to regenerate through the application of precisely controlled magnetic field pulses. The pulses stimulate tissues to repair themselves. In its most general form, the technique is often referred to as Pulsed Electro‐Magnetic Field (PEMF) therapy.
This new American-developed technology is the result of scientific research and development that evolved from programs funded by NASA (National Aeronautics and Space Administration) in the 1990s. After several years of research and development of the PEMF technology, radical design enhancements, and several new patents, this technology is now being introduced for use with both humans and animals.
This technology has been shown to create axonal (nerve fiber) growth in culture and to double the rate of production of ECM (extracellular matrix (the connective structure between cells) in scientific studies. New ongoing scientific work is underway to further validate the findings and to continue to improve the technology.
[/vc_column_text][vc_single_image image=”140″ img_size=”full” alignment=”center” style=”vc_box_shadow_border”][vc_custom_heading text=”Principles:” font_container=”tag:h3|text_align:left” use_theme_fonts=”yes”][vc_column_text]
The electromagnetic stimulation device is based on known laws of classical physics from Maxwell’s equations, specifically Faraday’s Law of Induction, as well as both classical quantitative physiology of excitable tissues and modern theories on functional adaptation in musculoskeletal, cardiovascular, neurological and other structural tissues.
It is known that muscle and nerve tissues respond directly to electrical excitation by the trans-membrane cascade of ions; this results in the propagation of action potentials in nerves or in contraction in muscles. It is also hypothesized, that most structural tissues, especially bone, tendon, ligament, articular cartilage, and perhaps skin, respond to selective ion flow in the paracellular space between the cell membrane and the extracellular matrix (ECM) when the tissue is subjected to mechanical stress. This ion flow is the presumptive signal that initiates the cellular-level response leading to functional adaptation, repair, and regeneration of structural tissues.
The electromagnetic stimulation works by using Faraday’s law of induction which says that the first time derivative of the magnetic field is proportionally related to the induced electric field. It is this law that makes things work like electrical transformers, electric motors, and magnetic audio and videotape. Based on these known laws it has been calculated the type of magnetic field necessary to generate an induced electrical field in the paracellular space around each cell that is in the right range of amplitude and duration to elicit a cellular response. These calculations are based on classical physiology where the amplitude is equal to Rheobase and duration is equal to Chronaxie.
There is an abundance of literature, at least 800 peer-reviewed papers, supporting the fact that electrical shock and electrical currents can induce significant acceleration of restoration in tissues. But the problem has always been (a) locating electrodes close enough to and properly placed to be stimulated electrically and (b) the fact that free electrical current follows a random path of least resistance resembling a lightning bolt. A few cells directly in the path of the “lightning bolt” will be hyper-stimulated, while the other 99% of cells outside the “lightning bolt” receive essentially no stimulation. The application of magnetic fields solves these two problems. It applies magnetic fields (not direct electrical stimulation) mainly because they do NOT interact directly with the tissues of the body. And the device rapidly changes the strength of the magnetic field. This is in contrast to the common fixed-strength magnet bracelets and similar trinkets, which do not work beyond any observable placebo effect. The magnetic field is applied to a volume of tissue using two small coils and then rapidly changes the magnetic field so that it has the optimum level of induced electrical field amplitude (“Rheobase”, calculated from Faraday’s equation) and optimum duration ( “Chronaxie”).
[/vc_column_text][vc_column_text]Uniform cell stimulation
The roughly uniform magnetic field applied over a volume of tissue and then carefully controls the rapid changes in the magnetic field to induce the desired electrical field in that same volume of tissue. It therefore uniformly stimulates all cells in the affected volume with roughly equivalent electromotive force on the ions in the paracellular and para nuclear spaces. This uniform stimulation thereby emulates the effects of mechanical stress on the tissues (that presumably signal by ion flux in the paracellular space and through voids and conduits in the ECM). The very significant difference between the electromagnetic system and electrical stimulation, in general, is in the uniformity of the stimulation: unlike electrical stimulation, there is no “lightning bolt” path of hyperstimulated cells. Instead, all cells in the affected volume receive a nearly uniform level of stimulation, just as they would during mechanical stress from the environment.
Tissue subjected to minimum stress
Electromagnetic stimulation brings ion flow from simulated mechanical stress without actually applying mechanical stress, the tissue does not get subjected to additional stresses. With severely damaged tissue even low levels of additional stress can be counter-productive. Also, with damaged tissues, the mechanisms for conducting mechanical stress in a helpful way to elicit the functional adaptive response have often been disrupted. It is believed this is why some serious injuries are refractory to recovery: they are no longer capable of supporting the mechanical stress field necessary to evoke an adaptive regenerative response at the cellular level. It is possible that the thresholds for these responses also increase with age, making it more difficult to evoke adaptive regeneration with increasing age beyond maturity.
It delivers a simulated paracellular ion flux response as though the tissue were intact and healthy, even if the tissue is badly damaged.
Safe, low-power system
The electromagnetic stimulation emits very low levels of power because the induction-coupled system is uniform and well-controlled in the volume of tissue to be stimulated. It has been optimized to provide optimum stimulation effect at low power output levels. In fact, its output is only about 350 milliwatts or about a third of the power of a typical cell phone.
Pulse output tuned to be truly effective
Right calculation and tuning of the magnetic pulses to induce electrical fields that make sense physiologically to the cells being stimulated. The pulse amplitude and duration are carefully selected based on Rheobase and Chronaxie measurements mentioned above, and the repeating patterns of these pulses are selected based upon known motor-neuron stimulation patterns for musculoskeletal tissues. Both fast-twitch (power) and slow-twitch (postural) muscular activity are emulated.
[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row]